SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring
to the operator(s) is complete. Whenever any of the programming switches on the circuit board are
changed, power must be shut-off, and then turned back on for the new setting to take effect.
Set the DIP-switches on the circuit board to the desired setting. See switch-setting charts in
section 3.2.
Auto close timer (when turned on) can be set from 1 second (full counter clockwise) to
approximately 23 seconds (full clockwise).
Dry contact relay (terminals 15-16) can be set for Normally Open (NO) or Normally Closed
(NC) operation by placing the relay shorting bar on the NO or NC pins respectively.
Power LED indicates that low voltage power is applied to the circuit board. Input LEDs should
be OFF and will only illuminate when the input is activated. The pulse LEDs will blink as the
operator is running. They can be either ON or OFF when the operator is stopped.
3.1 CIRCUIT BOARD ADJUSTMENTS
OPEN Loop Port REVERSE Loop Port
TIMER ADJUST
POWER LED
REVERSE
SENSITIVITY
COUNTER
LED's
RELAY CONTACT
PROGRAMMING
SWITCHES
AUXILIARY
TERMINALS
INPUT LED's
Figure 34