Secondary entrapment protection devices must be installed to insure a safe operating environment
and to reduce the risk of entrapment. This operator has inputs for non-contact sensors and contact
sensors for both opening and closing gate cycles. Secondary entrapment protection may be provided
by a combination of both type sensors. See Section 5.3 for a list of acceptable secondary entrapment
protection devices.
2.3.1 NON-CONTACT SENSORS
Disconnect power to the gate operator before installing the non-contact sensors.
See figure 26 for suggested placement of sensors. (Diagram is for illustration purposes only.
Actual placement of the sensors is dependent on the installation requirements). One or more
non-contact sensors shall be located where the risk of entrapment or obstruction exists, such
as the perimeter reachable by a moving gate or barrier.
Use only UL listed (or equivalent) non-contact sensors.
Connect the non-contact sensors as shown below to the auxiliary terminal strip located on the
4602 control board. Inputs from photo-beam to circuit board are NORMALLY OPEN.
Diagram does not show power wiring to photo-beams.
Open photo-beam must be placed so that it covers that portion of the fence that the gate
covers when it is fully open.
2.3 SECONDARY ENTRAPMENT PROTECTION DEVICE WIRING
Roadway
Fence
Gate
Open direction
non-contact sensor
Close direction
non-contact sensor
Open Photo-Beam
Close Photo- Beam
Open Edge
Close Edge
Common
Close Direction Protection
Open Direction Protection
Figure 26