6500-065-W-3-14
18
3.2 DIP-Switch Settings for 4405 Circuit Board
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then
turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
Switch Function Setting Description
SW 1 (Top 8 Switches)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
7-OFF
7-OFF
7-ON
7-ON
8-OFF
8-ON
8-OFF
8-ON
Auto-Close
Timer
Single Operator
Dual Operators
Circuit
Board
Relay
See next page for ALL 12 switch definitions and typical settings.
1
2
3
4
5
6
7 and 8
The output wired to terminal #4 becomes the output from the exit loop detector
plugged into the EXIT Loop port.
Normal Setting. Terminal #4 is a normal full open input.
Auto-close timer is OFF. Manual input required to close gate.
Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds.
Normal Setting. Switch must be OFF for single operator.
Switch must be ON when primary/secondary (dual) gates are used.
Normal Setting. Relay activates when gate is at open limit.
(Shadow loop setting when DoorKing Plug-In loop detector is used)
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates during opening and closing cycle.
Reverses Gate
External Shadow
Loop Detector
Exit Loop Port
Output
Full Open Input
Normal Setting. Input to terminal #6 and reverse loop will stop and reverse gate to
the full open position during the close cycle ONLY.
Input to terminal #6 becomes a SHADOW loop input. It is only active when the gate
is fully opened. (Shadow loop setting when external loop detector is used)
Switch Function Setting Description
SW 2 (Bottom 4 Switches)
Normal Setting. Switch 3 MUST be turned OFF for Model 6500 operator.
Normal Setting. Switch 4 MUST be turned OFF for Model 6500 operator.
OFF
ON
OFF
ON
OFF
OFF
Magnetic lock
1
2
3
4
Normal Setting. Magnetic lock is not used.
Magnetic lock is used and connected to terminals 9 and 12. See page 27 for wiring.
Gate Overlap
Primary and secondary operators start at the same time (Normal setting for single
gate operator).
The secondary operator will start 1.5 sec. before primary operator during open
cycle and the primary operator will start 1.5 sec. before the secondary operator
during the close cycle (Normal setting for bi-parting gate operators).
Primary 6500
Changes Gate
Opening
Direction
Same as above, for secondary 6500 ONLY.
Secondary 6500
Changes Gate
Opening
Direction
ON OFF
Opens
Clockwise
Opens
Counter-Clockwise